What is JXF Control Box?
The JXF control box is equipped with multiple protection functions including overload protection, short-circuit protection, phase loss protection, pump water leakage protection, motor over-temperature protection and electric leakage protection, as well as complete status display functions. It supports single-pump and multi-pump control modes, multiple main and standby pump switching methods and various starting modes. It is widely applicable to automatic control scenarios such as water supply, drainage, fire protection, spray pipe network pressurization, and HVAC cold and hot water circulation in agricultural production and various buildings.
The water pump control box features reliable internal quality, beautiful and durable appearance, and convenient installation and operation, serving as a safe and reliable matching device for various water pumps.
Power supply: municipal power, self-provided power grid, diesel generator set;
Three-phase AC 380V (-10%, +15%), 50HZ;
Applicable motor: general squirrel-cage asynchronous motor;
Protection grade: IP41 or IP20;
Altitude: no more than 2000 meters (derating use is required if exceeding 2000 meters);
Ambient temperature: -25°C ~ +40°C;
Relative humidity: no more than 95%, no condensation;
Vibration: less than 0.5G;
Wide application: Special models and specifications are available for various scenarios, including domestic water supply and drainage, fire protection, spray pressurization, air conditioning cooling circulation, industrial control pumps and sewage discharge.
Controllable motor power: 0.18~250KW;
Excellent quality: Adopts well-known domestic and international brand electrical components and high-quality standard cabinets with elaborate design and precise manufacturing;
Diversified functions: Supports control modes from one-pump control to five-pump control, arbitrary combination of main and standby pumps, multiple starting methods, various control forms and automatic fault switching.
|
Parameter Item |
Standard Specification |
|
Rated Operating Voltage |
AC220V/380V (Maximum insulation voltage 690V) |
|
Applicable Frequency |
50Hz |
|
Maximum Rated Current |
Conventional ≤400A, conventional complete circuit within 250A |
|
Short-time Withstand Breaking Current |
6kA~15kA |
|
Standard Protection Grade |
Indoor surface-mounted IP43/IP40; Outdoor JFF rainproof type IP54~IP65 |
|
Executed National Standards |
GB 7251.1、IEC 60439-1、GB/T17466 |
|
Installation Category |
Class Ⅱ; Pollution Level 3 |
JXF base control boxes are named by height + width in the industry. The box depth adopts general standard dimensions and supports non-standard customization. The following summarizes the common standard models, overall dimensions and conventional depth parameters widely used in the market:
|
Common Model Code |
Box Height (mm) |
Box Width (mm) |
Standard Conventional Depth (mm) |
Application Scenario Description |
|
2520 |
250 |
200 |
140/180 |
Small weak current control, single-circuit lighting, small signal conversion |
|
3025 |
300 |
250 |
140/180 |
Small single water pump control, simple equipment start-stop, household and store power distribution |
|
3030 |
300 |
300 |
140/180/200 |
Ordinary single pump control, multi-circuit lighting power distribution, small power control |
|
4030 |
400 |
300 |
180/200 |
Conventional water pump control box, fan control, workshop terminal power distribution (the most universal model) |
|
4040 |
400 |
400 |
180/200/230 |
One-use-one-standby water pump control, complete control with instruments and buttons, multi-circuit power distribution |
|
5040 |
500 |
400 |
200/230 |
Multi-pump control, high-power motor start-stop, complete set with frequency conversion / simple PLC control |
|
6040 |
600 |
400 |
200/230 |
1-to-3 / 1-to-4 multi-pump linkage, fire pressure stabilizing pump complete control |
|
6050 |
600 |
500 |
200/230 |
Complex multi-pump system, remote control with communication function, high-power complete power equipment |
|
7050 |
700 |
500 |
230 |
1-to-5 multi-pump unit, star-delta / auto-decompression starting control cabinet |
|
8060 |
800 |
600 |
230 |
High-power water pump complete set, multi-circuit centralized control, industrial equipment main control box |
1. Surface Mount (Most Commonly Used)
The box is directly fixed on the wall with expansion bolts with the whole body exposed. It features simple construction and convenient later maintenance, which is the preferred installation method for most engineering and equipment control scenarios.
2. Flush Mount (Embedded Type)
The box is pre-embedded inside the wall with only the door exposed. It is widely used for decoration and finishing weak current and household strong current distribution boxes. The box size is indented on four sides to reserve plastering margin.
1. Calculate the overall size of internal electrical components and reserve more than 20% wiring space to avoid insufficient space for wiring and heat dissipation caused by undersized box.
2. Ordinary indoor JXF boxes are prohibited for open-air outdoor environments; JFF rainproof boxes with eaves must be adopted.
3. Stainless steel cabinets are preferred for humid basements and water treatment environments.
4. For high-current circuits (above 200A), thickened box plates and widened mounting base plates are recommended to prevent thermal deformation.
5. All boxes must be reliably grounded, and the box shell shall be connected with PE protective ground wire.
Q1: What is the difference between JXF and JFF control boxes?
A1: JXF is an indoor wall-mounted control box with IP40/IP43 protection grade, suitable for indoor dry environments; JFF is an outdoor rainproof upgraded version with rain eaves, reaching IP54~IP65 protection grade, specially used for outdoor open-air installation.
Q2: What power range of water pumps can the JXF control box support?
A2: It can control squirrel-cage asynchronous motors with a power range of 0.18KW to 250KW, covering small household pumps, medium-sized domestic water supply and drainage pumps, and large industrial and fire water pumps.
Q3: Can the JXF control box be used in humid environments?
A3: Standard cold-rolled steel JXF boxes are only suitable for conventional indoor environments. For humid, corrosive or water treatment scenarios, customized 304 stainless steel boxes are required to prevent rust and corrosion.
Q4: Does the equipment need derating operation at high altitude?
A4: The standard applicable altitude is within 2000 meters. When the installation altitude exceeds 2000 meters, air density decreases and heat dissipation weakens, so the equipment must operate with derating power.
Q5: What protection functions does the JXF water pump control box have?
A5: It integrates multiple core protections including overload, short circuit, phase loss, motor over-temperature, pump body water leakage and electric leakage, with complete running and fault status display to ensure safe operation of water pump units.
Q6: Are standard box sizes customizable?
A6: All conventional models support non-standard customization of length, width and depth. Special sizes can be customized according to component layout, on-site installation space and heat dissipation requirements.